2 resultados para Porcine circovirus-2

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Porcine S100A12 is a member of the S100 proteins, family of small acidic calcium-binding proteins characterized by the presence of two EF-hand motifs. These proteins are involved in many cellular events such as the regulation of protein phosphorylation, enzymatic activity, protein-protein interaction, Ca(2+) homeostasis, inflammatory processes and intermediate filament polymerization. In addition, members of this family bind Zn(2+) or Ca(2+) with cooperative effect on binding. In this study, the gene sequence encoding porcine S100A12 was obtained by the synthetic gene approach using E. coli codon bias. Additionally, we report a thermodynamic study of the recombinant S100A12 using circular dichroism, fluorescence and isothermal titration calorimetry. The results of urea and temperature induced unfolding and refolding processes indicated a reversible two-state process. Also, the ANS fluorescence studies showed that in presence of divalent ions the protein exposes hydrophobic sites which could facilitate the interaction with other proteins and trigger the physiological responses. (c) 2008 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We describe the development of a label free method to analyze the interactions between Ca(2+) and the porcine S100A12 protein immobilized on polyvinyl butyral (PVB). The modified gold electrodes were characterized using cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), scanning electron microscopy (SEM) and surface plasmon resonance (SPR) techniques. SEM analyses of PVB and PVB-S100A12 showed a heterogeneous distribution of PVB spherules on gold surface. EIS and CV measurements have shown that redox probe reactions on the modified gold electrodes were partially blocked due the adsorption of PVB-S100A12, and confirm the existence of a positive response of the immobilized S100Al2 to the presence of calcium ions. The biosensor exhibited a wide linear response to Ca(2+) concentrations ranging from 12.5 to 200 mM. The PVB-S100A12 seems to be bound to the gold electrode surface by physical adsorption: we observed an increase of 1184.32 m degrees in the SPR angle after the adsorption of the protein on the PVB surface (in an indication that 9.84 ng of S100A12 are adsorbed per mm(2) of the Au-PVB electrode), followed by a further increase of 581.66 m degrees after attachment of the Ca(2+) ions. In addition, no SPR response is obtained for non-specific ions. These studies might be useful as a platform for the design of new reusable and sensitive biosensing devices that could find use in the clinical applications. (C) 2010 Elsevier B.V. All rights reserved.